The ECO HOME SERIES Split EVI DC Inverter Units is designed especially for European markets where there is a demand for Space heating/ Cooling + Hot water. This unit can realize space heating &Sanitary hot water supply through terminal units, like the Fan coil unit, Floor coil & Radiator. It is widely applicable to small & medium-sized apartments, large-sized villas, etc.
The whole series of products are strictly comply with EN14511 standard,EUROVENT Energy efficiency Class A and SCOP Class A+++ (35t℃, SCOP CLASS A++(55℃) With EN14825Standard
Equipped perfect Automatic system with a reverse valve inside for defrosting which can let the units stably work under ambient temperature of 30 Centigrade. At the same time, it will make optimal decisions on whether it is time to defrost or not. ln, this way. the unit is able to minimize energy consumption.
Specification
Product model |
PW060-DKZLRS-C |
|
Heating |
Heating Capacity Range (kW) |
10.5~22 |
Heating input Range (kW) |
2.27~5.2 |
|
current Range (A) |
4.06~9.30 |
|
COP Range |
4.23~4.63 |
|
Cooling |
Cooling capacity Range (kW) |
7.2~14.2 |
Cooling input power(kW) |
2.17~5.55 |
|
Current Range (A) |
3.88~9.93 |
|
EER Range |
2.56~3.32 |
|
DHW |
Heating Capacity Range (kW) |
8.8~17.5 |
Heating input Range (kW) |
2.24~5.61 |
|
current Range (A) |
4.01~10.0 |
|
COP Range |
3.12~3.93 |
|
Refrigerant |
R32 |
|
Power supply |
380V/3Ph/50-60Hz |
|
Working area |
-30~43℃ |
|
Water pressure drop (kPa) |
30 |
|
IP Grade (Level of protection) |
IPX4 |
|
Anti-electric shock Rate |
I |
|
Noise (dB(A)) |
≤58 |
|
Net weight/Gross weight(kg) |
140/155 |
|
Body size(W*D*H) (mm) |
1000×480×1380/ |
|
ERP Level (35°C) |
A+++ |
|
ERP Level (55°C) |
A++ |
|
Water Head(m) |
12m |
|
Expansion Tank(L) |
5L |
|
Electric Heater(kW) |
3 |
|
Operating water temperature (℃) DHW |
20~55℃ |
|
Operating water temperature (℃) heating |
20~50℃ |
|
Operating water temperature (℃) cooling |
7~35℃ |
http://www.powerworldhp.com/